ANY-maze Help > The ANY-maze reference > The Protocol page > The elements of a protocol > Analysis > Analysis options > Specifying the results that ANY-maze should analyse in the OPAD cage Specifying the results that ANY-maze should analyse in the OPAD cage
IntroductionWhen tests are performed in an OPAD cage, ANY-maze will report some OPAD-specific results; specifically, the Temperature when contact is broken and Temperatures of interest. The Analysis of OPAD results element in the protocol is used to define exactly how these results are generated.
Temperature when contact is brokenThe Temperature when contact is broken essentially reports the temperature of the OPAD cage thermal elements when the animal broke contact - which usually occurs because the thermal stimulus had become too aversive. Of course, an animal might make and break contact multiple times - the result reported is the average for all the occasions when the animal broke contact. Selecting the 'breaks' of interestIn OPAD tests, you will typically be ramping the temperature of the thermal elements up from around room temperature to some 'hot' value, or down to some 'cold' value. In the case where the temperature is ramping up, you will probably want to know when the temperature became aversively hot, causing the animal to break contact; and in the case where the temperature is ramping down, you would want to know when it became aversively cold. It would seem that the 'Temperature when contact is broken' is exactly the value you need to report this 'aversive temperature', but it's important to understand that by default, this will report the average temperature of ALL breaks, not just those that occurred when the temperature was ramping towards an aversive condition. To address this, you can specify that the average should only include breaks which occur when the temperature is ramping up and is above some value (or is ramping down and is below some value). For example, let's imagine that the temperature starts at 25°C, ramps up to 50°C, then drops back to 25°C before going back up to 50°C again, and that this repeats 10 times during the test. In this case, you will probably not be interested in breaks that occur below 30°C (when the temperature is not aversive); nor will you be interested in breaks that occur when the temperature is going back down from 50°C to 25°C. So, you could specify that the 'Temperature when contact is broken' should just include those breaks that occur when the temperature is ramping UP and is above 30°C. Ignoring short contacts or short breaksWhen the animal breaks contact (because the thermal elements have become aversively hot or cold), it may wait a moment and then make contact again - however, it will probably immediately break contact because the element will still be too hot or cold. Thus, you may see a long period of contact (while the device has not reached an aversive temperature), followed by a break, and then followed by a few short contacts. When analysing the 'temperature when contact is broken', you would probably say that the temperature when the first of these breaks occurs is the temperature you want to use; in other words, you would want to ignore the very short contacts that follow it. To achieve this, you simply need to specify that ANY-maze should Only include a break if the animal has been in contact for at least a certain period of time - for example, 5 seconds. OPAD will detect all breaks in contact, even if the break only lasts a very short time. However, this may not be very appropriate; for example, the animal might be in contact for 30 seconds, then move its position very slightly, causing a brief break, and then resume contact for another long period - in this case, you probably wouldn't want this short 'break' to be used in calculating the Temperature when contact is broken. To address this, you can specify that breaks of less than a certain duration should be ignored - for example, you could ignore any break that lasts less than 1 second. Temperatures of interestAs the name implies, a 'Temperature of interest' is a temperature range which interests you. For example, you may have determined that animals typically break contact with the thermal element when it is at around 40°C, but when you give them a certain drug, this increases to 50°C. This being the case, you might decide to create two 'temperatures of interest' - one for the range 35-45°C, and another for the range 45-50°C. For each temperature of interest that you define, ANY-maze will report:
To specify a temperature of interest you simply need to enter a temperature range in °C, for example from '40' to '45'. A range must cover at least 1°C, so for example you can't specify a range from '40' to '40'. You can enter as many ranges as you like, and they can overlap, so specifying one range from 40-50 and another from 45-50 is OK. To remove a range, just delete the From and To values. Editing the analysis optionsThe options for both the Temperature when contact is broken and Temperatures of interest can be edited at any time, including after tests have been performed. Any changes you make will immediately cause the experiment's data to be re-analysed, and the results will then update automatically.
© Copyright 2003-2026 Stoelting Co. All rights reserved ANY-maze help topic T0657 |