ANY-maze will score the following measures for a light controller:

 Number of activations 
 Time active 
 Latency to first activation 
 Latency to first deactivation 
 Longest activation 
 Shortest activation 
 Average activation duration 
 Frequency of activations  

  

Each measure is available for the apparatus as whole (i.e. irrespective of where the animal was when the light controller activation occurred), and also for each defined zone.

  

  

Number of activations

DescriptionReports the number of times the light controller was activated.
Calculation methodCounts the number of activations.
Analysis in zonesCounts the number of activations when the animal was in the zone.
Analysis across timeThis measure can be analysed across time. For any time period, the result is the number of activations during the time period.
UnitsNone
NotesNone

  

  

Time active

DescriptionReports the total amount of time that the light controller was active.
Calculation methodSums the amount of time for which the light controller was active.
Analysis in zonesSums the amount of time for which the light controller was active while the animal was in the zone.

For a particular zone, it's possible for the Time active to be non-zero while the Number of activations is zero. This can occur if the animal enters the zone when the light controller is active. In this case, the time the light controller is active will be registered but the activation itself won't be.

Analysis across timeThis measure can be analysed across time. For any time period, the result is the amount of time that the light controller was active during the period.

For a particular time period, it's possible for the Time active during the period to be non-zero while the Number of activations for the period is zero. This can occur if the light controller is already active at the start of the period. In this case, the time the light controller is active will be registered but the activation itself won't be.

UnitsSeconds
NotesNone

  

  

Latency to first activation

DescriptionReports the amount of time that elapsed in the test before the light controller was activated for the first time.
Calculation methodThe value of the test clock at the first activation of the light controller.
Analysis in zonesThe value of the test clock at the first activation of the light controller that occurred while the animal was within the zone.
Analysis across timeThis measure cannot be analysed across time.
UnitsSeconds
NotesNone

  

  

Latency to first deactivation

DescriptionReports the amount of time that elapsed in the test before the light controller was deactivated for the first time.
Calculation methodThe value of the test clock at the first deactivation of the light controller.
Analysis in zonesThe value of the test clock at the first deactivation of the light controller that occurred while the animal was within the zone.
Analysis across timeThis measure cannot be analysed across time.
UnitsSeconds
NotesNone

  

  

Longest activation

DescriptionReports the duration of the longest period for which the light controller was continuously active.
Calculation methodThe duration of each light controller activation is calculated and the largest value is found.
Analysis in zonesThe longest period for which the light controller was continuously active while the animal was in the zone.
Analysis across timeThis measure can be analysed across time. For any time period, the result is the longest period for which the light controller was continuously active during the period.
UnitsSeconds
NotesNone

  

  

Shortest activation

DescriptionReports the duration of the shortest period for which the light controller was continuously active.
Calculation methodThe duration of each light controller activation is calculated and the smallest value is found.
Analysis in zonesThe shortest period for which the light controller was continuously active while the animal was in the zone.
Analysis across timeThis measure can be analysed across time. For any time period, the result is the shortest period for which the light controller was continuously active during the period.
UnitsSeconds
NotesNone

  

  

Average activation duration

DescriptionReports the average duration for which the light controller was active.
Calculation methodCalculated by dividing the Time active by the Number of activations.
Analysis in zonesThis measure cannot be analysed in zones.
Analysis across timeThis measure cannot be analysed across time.
UnitsSeconds
NotesNone

  

  

Frequency of activations

DescriptionReports the frequency with which the light controller was activated.
Calculation methodCalculated by dividing the Number of activations by the Test duration.
Analysis in zonesCalculated by dividing the Number of activations in the zone by the Total time in the zone.
Analysis across timeThis measure can be analysed across time. For any time period, the result is the Number of activations which occurred during the period divided by the period's duration.
UnitsHertz
NotesNone

See also:

 Information measures 
 Apparatus measures 
 Zone measures 
 Point measures 
 Sequence measures 
 Key measures 
 On/off input measures 
 Rotary encoder measures 
 Signal measures 
 Sensor measures 
 Movement detector measures 
 On/off output measures 
 Speaker measures 
 Shocker measures 
 Pellet dispenser measures 
 Laser controller measures 
 Syringe pump measures 
 OPAD measures 
 Procedure measures 
 Event measures 
 Virtual switch measures 

© Copyright 2003-2026 Stoelting Co. All rights reserved

ANY-maze help topic T0300